Circuit breaker size S00
Circuit breaker size S00 for motor protection offers reliable shutdown in case of short-circuits and overload protection.
Technical details:
- CLASS 10 A-release 0.45...0.63 A N-release 8.2 A
- Standard switching capacity
- Circuit breaker SIRIUS 3RV2
- Optimized for use in load feeders, as well as for IE3/IE4 motors
- Worldwide approvals (e.g. IEC and UL/CSA)
- Applications in hazardous areas (ATEX or IEC Ex)
- Available versions for motor protection (also with overload relay function)
- Plant protection, short-circuit protection of starter combinations
- Transformer protection, as main and EMERGENCY OFF switches
- For use in IT networks
- Screw or spring-type terminals for fast, maintenance-free and vibration-proof connection
- Optionally with integral auxiliary switch
- Comprehensive range of standardized accessories
- Associated SIRIUS 3RV29 infeed system reduces main circuit wiring
- 3RV2 circuit breakers replace the well-proven 3RV1 series
Customer benefits:
- Reliable shutdown in the event of a short-circuit
- Protection against overload
- Safe isolation of the system from the network
- Low heat loss
- Compact and climate-proof design
- Simple, efficient and always up to date with the SIRIUS modular system
Disclaimer: Generated by AI.
Documente
Specificatii
| Electrical | |
| With integrated under voltage release | No |
| Number of poles | 3 |
| Rated operation power at AC-3, 230 V | 0.1 |
| Rated short-circuit breaking capacity Icu at 400 V, AC | 100 |
| Rated operation power at AC-3, 400 V | 0.18 |
| Rated operating voltage | 690 |
| Overload release current setting | 0.45 |
| Power loss | 5.5 |
| Rated permanent current Iu | 0.63 |
| Adjustment range undelayed short-circuit release | 8.2 |
| Other | |
| Switch off technique | Magnetic |
| Device construction | Built-in device fixed built-in technique |
| Measurements | |
| Width | 45 |
| Depth | 97 |
| Height | 97 |
| Protection | |
| Degree of protection (IP) | IP20 |
| Connection | |
| Type of electrical connection of main circuit | Screw connection |
| Options | |
| Phase failure sensitive | Yes |
| Model/type | |
| Type of control element | Other |
| With thermal overload protection | Yes |
| With integrated auxiliary switch | No |
| Package 1 | |
| weight | 0,28 |
| length | 0,102 |
| width | 0,049 |
| qmax | 1 |
| qmin | 1 |
| um | PA |
| gtin | 4011209712379 |
| Package 2 | |
| volume | 0,026 |
| weight | 8,272 |
| length | 0,44 |
| width | 0,325 |
| qmax | 28 |
| qmin | 28 |
| um | CT |
| gtin | 4011209712379 |
| Dimensions of product | |
| Weight | 0,28 |