LOGO! 24CE, logic module, display power supply / I/O: 24 V/24 V/24 V trans., 8 DI (4 AI)/4 DO
Cod produs: 6ED1052-1CC08-0BA2
Descriere
LOGO! 24CE
The LOGO! 24CE is a versatile logic module with integrated web server capabilities, designed for efficient control and monitoring of connected loads.
Technical details:
- Display power supply / I/O: 24 V/24 V/24 V trans.
- 8 DI (4 AI)/4 DO
- Memory: 400 blocks
- Modularly expandable
- Integrated Ethernet web server
- Data log
- User-defined web pages
- Standard microSD card for LOGO! Soft Comfort V8.4 or higher
- Older projects executable cloud connection
- MQTT in all LOGO! 8.4 basic units
- Installation width: 72 mm
- Up to 24 DI / 20 DO (8 AI / 8 AQ)
- Up to 10 A rating for outputs
- Cloud communication integrated
Customer benefits:
- Seamless communication between up to nine LOGO! 8 modules or SIMATIC S7 systems.
- Easy creation and simulation of switching programs on PC.
- Monitoring and control of connected loads over WLAN or Internet.
- Customizable web pages can be designed without HTML knowledge.
- GSM or GPS communication and integration in KNX building management systems are possible.
- Expansion possibilities with external text display for clear message visibility.
- Selectable color for backlit display for visual emphasis.
Disclaimer: Generated by AI.
Documente
Specificatii
| Electrical | |
| Power consumption | - |
| Switching current | 0.3 |
| Voltage type (supply voltage) | - |
| Supply voltage AC 50 Hz | - |
| Supply voltage AC 60 Hz | - |
| Supply voltage DC | 20.4 |
| Approval/certification | |
| Certified for UL hazardous location class I | - |
| Certified for UL hazardous location class II | - |
| Certified for UL hazardous location class III | - |
| SIL according to IEC 61508 | - |
| Certified for UL hazardous location group A (acetylene) | - |
| Certified for UL hazardous location group B (hydrogen) | - |
| Certified for UL hazardous location group D (propane) | - |
| Certified for UL hazardous location group C (ethylene) | - |
| Certified for UL hazardous location group F (carbonaceous dusts) | - |
| Certified for UL hazardous location division 2 | - |
| Certified for UL hazardous location division 1 | - |
| Certified for UL hazardous location group G (non-conductive dusts) | - |
| Communication | |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | No |
| Number of HW-interfaces industrial Ethernet | 1 |
| Number of HW-interfaces RS-422 | 0 |
| Number of HW-interfaces RS-232 | 0 |
| Number of HW-interfaces serial TTY | 0 |
| Number of HW-interfaces RS-485 | 0 |
| Number of HW-interfaces parallel | 0 |
| Number of HW-interfaces USB | 0 |
| With optical interface | No |
| Number of HW-interfaces other | 0 |
| Number of interfaces PROFINET | 0 |
| Supporting protocol for SERCOS | No |
| Number of HW-interfaces wireless | 0 |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for EtherCAT | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for ASI | No |
| Supporting protocol for TCP/IP | Yes |
| Supporting protocol for CAN | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for LON | Yes |
| Mounting/installation | |
| Wall mounting/direct mounting | Yes |
| Suitable for rail mounting | Yes |
| Front built-in possible | Yes |
| Model/type | |
| With display | Yes |
| With time switch clock | Yes |
| Basic device | Yes |
| With relay output | No |
| Expansion device | No |
| Protection | |
| Certified for UL hazardous location group E (metal dusts) | - |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Degree of protection (IP) | IP20 |
| Performance | |
| Performance level according to EN ISO 13849-1 | - |
| Options | |
| Redundancy | No |
| Mobile communications standard 3G (UMTS) | No |
| Radio standard GSM | No |
| Radio standard GPRS | No |
| Expandable | Yes |
| Radio standard WLAN 802.11 | No |
| IO link master | No |
| Radio standard Bluetooth | No |
| Rack-assembly possible | No |
| Measurements | |
| Width | 71.5 |
| Depth | 60 |
| Height | 90 |
| Other | |
| Appendant operation agent (Ex ib) | No |
| Appendant operation agent (Ex ia) | No |
| Connection | |
| Number of digital inputs | 8 |
| Number of digital outputs | 4 |
| Number of analogue inputs | 4 |
| Number of analogue outputs | 0 |
| Application | |
| Suitable for safety functions | No |
| Package 1 | |
| weight | 0,228 |
| length | 0,095 |
| width | 0,08 |
| qmax | 1 |
| qmin | 1 |
| um | PA |
| gtin | 4034106034498 |
| Dimensions of product | |
| Weight | 0,228 |